Description

The PR 2261 mV Transmitter from PR Electronics (Denmark) is a high-precision industrial signal conditioning module designed to convert low-level millivolt signals from load cells and sensors into standard analog outputs for PLC and control systems. The PR 2261 mV Transmitter ensures accurate signal amplification and conversion, making it ideal for industrial weighing, level monitoring, and process control applications. The PR 2261 mV Transmitter converts bipolar millivolt input signals from transducers into standard current or voltage outputs (0–20 mA / 0–10 V) used in automation systems. It features a front-programmable interface with a 3-digit LED display for easy configuration and calibration. Industrial buyers looking to buy PR 2261 mV Transmitter, find a PR Electronics distributor, or source a load cell signal converter replacement module benefit from its high stability, robust design, and reliable industrial performance.

Advanced Features

  • Converts bipolar mV signals to standard current or voltage outputs
  • Designed for load cell and strain gauge applications
  • Front-programmable interface with 3-digit LED display
  • Adjustable input span calibration
  • NPN / PNP digital input for external taring
  • Integrated transducer power supply (5–13 VDC)
  • High signal accuracy and stability
  • Built-in error indication LED

Applications

  • Load cell signal amplification
  • Industrial weighing systems
  • Tank filling and emptying control
  • Cable tension monitoring
  • Level measurement systems
  • Process signal conversion and amplification

Technical Characteristics

  • Input Range: –40 to +100 mV
  • Output Signals: 0–20 mA or 0–10 V
  • Supply Voltage: 19.2 – 28.8 VDC
  • Transducer Supply: 5–13 VDC
  • Response Time: 20 ms
  • Operating Temperature: –20°C to +60°C
  • Mounting: 11-pole socket / DIN rail adapter
  • Protection Class: IP50

Datasheet PR 2261 mV Transmitter

SKU: N/A Categories: , Brand:
Other
Channel(s)

A: Single, B: Double

Environmental Conditions

Operating temperature-20°C to +60°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degreeIP50

Mechanical specifications

Dimensions (HxWxD)80.5 x 35.5 x 84.5 mm (D is without pins)
Weight approx.130 g

Common specifications

Supply

Supply voltage19.2…28.8 VDC
Max. required power7.2 W
Internal power dissipation2.2 W

Response time

Response time (programmable)0.06…999 s
Signal / noise ratioMin. 60 dB
Updating time20 ms
Signal dynamics, input17 bit
Signal dynamics, output16 bit
Effect of supply voltage change< ±0.002% of span / %V
Temperature coefficient< ±0.01% of span / °C
Linearity error< 0.1% of span
Auxiliary voltage: Transducer supply5…13 VDC
Load (max.)230 mA
EMC immunity influence< ±0.5% of span

Input specifications

Common input specifications

Max. offset70% of selec. max. value

Voltage input

Measurement range-40…100 mV
Min. measurement range (span)10 mV
Input resis ce> 10 MΩ
Overrange0…999% of selected measurement range
NPN, digital inputPull up 24 VDC / 6.9 mA
PNP, digital inputPull down 0 VDC / 6.9 mA
Trig level low, NPN/PNP< 6 VDC
Trig level high, NPN/PNP> 10.5 VDC
Pulse length> 30 ms

Output specifications

Current output

Signal range0…20 mA
Min. signal range5 mA
Load (@ current output)≤ 600 Ω
Load stability≤ 0.01% of span / 100 Ω
Current limit< 23 mA
Voltage output through internal shuntSee manual for details