Dark Light
, , , , , , ,

PR 5331A Temperature Transmitter

Availability:

In stock (can be backordered)


2-wire programmable transmitter

Model: 5331A3B
Make: PR Electronics
Origin: Denmark

  • Version: 5331A3B
  • RTD, TC, Ohm, or mV input
  • Extremely high measurement accuracy
  • 1.5 kVAC galvanic isolation
  • Programmable sensor error value
  • For DIN form B sensor head mounting

253.00

In stock (can be backordered)

Application

  • Linearized temperature measurement with Pt100…Pt1000, Ni100…Ni1000, or TC sensor.
  • Conversion of linear resis ce variation to a s dard analog current signal, for ins ce from valves or Ohmic level sensors.
  • Amplification of a bipolar mV signal to a s dard 4…20 mA current signal.

IEPSOLnical characteristics

  • Within a few seconds the user can program PR5331A to measure temperatures within all ranges defined by the norms.
  • The RTD and resis ce inputs have cable compensation for 2-, 3- and 4-wire connection.
  • Continuous check of vital stored data for safety reasons.

Mounting / installation

  • For DIN form B sensor head or DIN rail mounting with the PR fitting type 8421.
Other
Weight0.5 kg
Dimensions25 × 15 × 15 cm

Environmental Conditions

Operating temperature-40°C to +85°C
Calibration temperature20…28°C
Relative humidity< 95% RH (non-cond.)
Protection degree (encl./terminal)IP68 / IP00

Mechanical specifications

DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm2 stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6
2…25 Hz±1.6 mm
25…100 Hz±4 g

Common specifications

Supply

Supply voltage8.0…35 VDC
Internal power dissipation25 mW…0.8 W

Response time

Response time (programmable)0.33…60 s
Voltage drop8.0 VDC
Warm-up time5 min.
ProgrammingLoop Link
Signal / noise ratioMin. 60 dB
AccuracyBetter than 0.1% of selected range
Signal dynamics, input19 bit
Signal dynamics, output16 bit
Effect of supply voltage change< 0.005% of span / VDC
EMC immunity influence< ±0.5% of span

Input specifications

Common input specifications

Max. offset50% of selected max. value

RTD input

RTD typePt100, Ni100, lin. R
Cable resis ce per wire (max.)10 Ω
Sensor current> 0.2 mA, < 0.4 mA
Effect of sensor cable resis ce (3-wire)< 0.002 Ω / Ω
Sensor error detectionYes

Linear resis ce input

Linear resis ce min….max.0 Ω…10000 Ω

Output specifications

Current output

Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply – 8) / 0.023 [Ω]
Load stability≤ 0.01% of span / 100 Ω
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE 43 Upscale/Downscale23 mA / 3.5 mA

Common output specifications

Updating time135 ms
*of span= of the presently selected range

Observed authority requirements

EMC2014/30/EU

Approvals

ATEX 2014/34/EUKEMA 10ATEX0003 X
IECExDEK 13.0036X
INMETRODEKRA 13.0002 X
CCOEP337392/3
EACTR-CU 020/2011
DNV-GL MarineS d. f. Certific. No. 2.4

Data sheet


Manuals


You may also like…

SHOPPING CART

close

Select at least 2 products
to compare